turbo_moc.fluent.stage.setup module#
Design the stage with the app pipeline and open a configured, unsolved 3D Fluent case.
- turbo_moc.fluent.stage.setup.solve(solver, options, velocities=('x-velocity', 'y-velocity', 'z-velocity'))[source]#
Initialize and run the staged solution strategy, each stage with its own order and time scale.
- turbo_moc.fluent.stage.setup.start_from_rest(settings, start, velocities=('x-velocity', 'y-velocity', 'z-velocity'))[source]#
Fluid at rest at the inlet total pressure, then the outlet pressure lowered step by step.
Near the saturated liquid the density falls by orders of magnitude through the stage; a hybrid initialization then starts far from a consistent field and the inlet reverses or the solver diverges. Ramping the outlet establishes the flow subsonically first.